Fire detection
In the Ave range of security systems, one of the most important places is certainly taken by the fire detection systems, since they represent the basic technical protection of every modern facility. With the consistent application of all measures and procedures prescribed by the Fire Protection Act, the use of stable automatic fire alarm installations would ensure timely notification in the initial stage of the fire and leave enough time to react in order to prevent spreading and the occurrence of damage.
Ave puts an emphasis on the fire protection of small and medium-sized buildings and offers reliable and high-quality solutions for timely fire detection, thus eliminating the occurrence of false alarms. All central units and all other fire detection equipment have been manufactured in accordance with the EN54 European standards.
Ave's offer includes addressable and conventional fire alarm central units. The addressable systems include the so-called operating consoles that can be used to control the system, review the condition of the system, and to signal the alarm at a remote location. The optical acoustic signallers are executed via light signalling boards and alarm sounders.
The central units, via their relay outputs, have the ability to work with various systems and electrical devices such as sprinkler systems for automatic fire extinguishing, GVK systems, sound alarms and fire alert systems, fire doors, fire dampers, elevators, etc.).
Fire detection systems can be integrated with the Ave smart home system using a special alarm interface, thus enabling visual and audible alarm signalling on the Touchscreen of home automation, saving the date and time of the alarm activation, and automatically activating the programmed scenarios in case of a fire (e.g. blackout, gas inlet closure, room desmoking, SMS alerts, etc.).
CONVENTIONAL CONTROL UNITS
- AC904 - 4 conventional lines (zones), 20 detectors per line, 2 alarm sounder outputs, relay output for general alarms, relay output for system faults, EN54...
ADDRESSABLE CONTROL UNITS
- AC921 – analogue microprocessor control unit with LCD display, 1 addressable loop with a capacity of 99 detectors + 99 modules, 20 zones, two outputs for alarm sounders, RS485, RS232, EN 54...
- AC922 – analogue microprocessor control unit with LCD display, 2 addressable loops with a capacity of 99 detectors + 99 modules per loop, 40 zones, two outputs for alarm sounders, RS485, RS232, EN 54...
- AC924 – analogue microprocessor control unit with LCD display, 4 addressable loops with a capacity of 99 detectors + 99 modules per loop, 40 zones, two outputs for alarm sounders, RS485, RS232, EN 54...
In addition to the central units, there are also all the basic types of smoke detector and the necessary accessories:
- operative panel (parallel tablo),
- optical addressable smoke detectors,
- optical-thermal addressable fire detectors,
- addressable rate of rise heat detectors,
- addressable break glass call points,
- conventional optical fire detectors,
- conventional thermal fire detectors,
- conventional break glass call points,
- input modules, output modules,
- input-output modules,
- parallel indicators,
- illuminated signalling signs,
- alarm sounders, etc.
For more information about the fire detection systems, please download the following documents:
| Ave safety systems - commercial catalogue |
| Ave Fire detection systems - brochure |